Introduction
Exhaust emission control has become an important concern in the shipping industry. Marine diesel engines produce various compounds during the combustion process, including nitrogen oxides (NOx), which contribute to air pollution. To reduce these emissions, modern ships widely use Selective Catalytic Reduction (SCR) technology, an exhaust gas treatment system that uses a urea solution as a reducing agent.
One solution used in marine applications is AUS 40 (Aqueous Urea Solution 40%). This product is a urea solution with a nominal concentration of 40%. It supports the NOx reduction process in Marine SCR systems. AUS 40 must meet specific quality requirements, particularly for urea concentration, density, refractive index, and impurity limits.
These requirements are regulated by the international ISO 18611 standard, which specifically addresses the quality and testing methods for NOx-reducing agents used in marine applications. Understanding the AUS 40 quality parameters under this standard is important for manufacturers, distributors, and ship operators to ensure that the solution meets the required specifications and does not interfere with emission control system performance.
1. Understanding ISO 18611 as the Quality Standard for AUS 40
ISO 18611 is an international standard that regulates the quality requirements for Marine NOx Reduction Agent AUS 40. It is designed to ensure that the urea solution used in marine SCR systems has the appropriate physical and chemical characteristics for exhaust gas treatment. ISO 18611 consists of several parts, with ISO 18611-1 covering quality requirements and ISO 18611-2 outlining the corresponding test methods.
AUS 40 has a nominal urea concentration of 40% by mass. It is used in SCR systems to produce ammonia, which then reacts with NOx on the catalyst surface. Through this process, nitrogen oxides are converted into nitrogen and water vapor, reducing their concentration in the exhaust gases.
Compliance with ISO 18611 is essential because the quality of the urea solution can affect the effectiveness of chemical reactions and the reliability of SCR components. Solutions with incorrect concentrations or excessive contaminants may interfere with the injection process, cause deposit formation, and affect catalyst performance.
The standard does not only regulate urea content but also specifies physical characteristics such as density and refractive index. In addition, it establishes maximum limits for certain impurities, including biuret, aldehydes, insoluble matter, phosphates, and several metallic elements. All these parameters help ensure that AUS 40 meets the required quality specifications before being used in ship emission control systems.
With measurable requirements in place, AUS 40 manufacturers and users have a consistent reference for production, inspection, distribution, and product acceptance. This helps maintain solution quality while supporting more reliable Marine SCR operations.
2. Main AUS 40 Quality Parameters: Urea Concentration, Density, and Refractive Index
AUS 40 quality is determined through several interrelated parameters. The three main parameters that need to be considered are urea concentration, density, and refractive index. These properties help ensure that the solution composition meets the required specifications and support quality inspections before the product is used.
Urea Concentration
Urea concentration is the main parameter that indicates the percentage of urea contained in AUS 40 by mass. According to ISO 18611-1:2014, the required urea content is within the range of 39–41%, with a target value of 40%. This means that every 100 kg of AUS 40 solution nominally contains approximately 40 kg of urea, with the remainder consisting of water.
This concentration is important because urea is the primary substance that produces ammonia during the exhaust gas treatment process. The ammonia then reacts with NOx on the SCR catalyst to help reduce these emissions. If the urea concentration is too low or too high compared with the specified range, the solution characteristics and system dosing settings may no longer match the SCR system’s requirements.
Therefore, urea concentration testing is necessary to ensure that AUS 40 remains within the specified range. Testing can be carried out using methods outlined in ISO 18611-2, including analytical methods based on refractive index measurements.
Density
Density refers to the mass of a solution per unit of volume at a specific temperature. Under ISO 18611-1, AUS 40 density is measured at 20°C, with a specified range of 1.105–1.177 kg/L. The target value is approximately 1.110 kg/L.
This parameter helps identify whether the physical characteristics of the solution meet the required specifications. Density can provide an initial indication of the solution’s composition, including possible changes in concentration or contamination. However, density measurements alone are not sufficient to confirm that every aspect of the solution’s quality complies with the standard.
In Marine SCR systems, density is also relevant to the storage and delivery of the solution. Changes in composition may affect the physical properties of AUS 40, making density measurement an important part of quality control. Measurements must be performed at the correct reference temperature because the density of liquids can change with temperature.
Refractive Index
The refractive index indicates how much a solution bends light as it passes through. In AUS 40, this value is related to the urea concentration and can therefore be used as one of the methods to verify whether the solution composition meets the required specifications.
According to ISO 18611-1:2014, the refractive index of AUS 40 at 20°C must fall within the range of 1.3947–1.3982, with a target value of approximately 1.3965. Measurements are performed using a refractometer in accordance with the testing methods specified in ISO 18611-2.
Refractive index testing helps detect possible changes in urea concentration. If the measurement falls outside the specified range, the sample should be examined further to identify the cause of the deviation. Factors such as changes in composition, contamination, and sample conditions may affect the measurement results.
These three parameters need to be assessed together. Urea concentration indicates the main composition of the solution, density provides information about its mass-to-volume characteristics, while refractive index helps verify concentration through its optical properties. Combining the test results allows AUS 40 quality inspections to be conducted more comprehensively.
In addition to these three main parameters, ISO 18611 also establishes limits for several impurities, including alkalinity, biuret, aldehydes, insoluble matter, phosphates, calcium, iron, magnesium, sodium, and potassium. Controlling these substances is necessary to maintain solution purity and reduce the risk of problems within the SCR system.

https://www.pexels.com/photo/a-person-writing-on-a-paper-7054510/
3. The Importance of AUS 40 Testing and Quality Control in Ensuring Specification Compliance and Supporting Marine SCR Performance
AUS 40 Testing to Ensure Specification Compliance
AUS 40 quality testing is an essential step in ensuring that products used on ships meet ISO 18611 requirements. These inspections are not limited to measuring urea concentration; they also verify that the solution’s physical and chemical properties remain within the specified limits. Consistent product quality helps ensure that the exhaust gas treatment process operates according to the SCR system’s design.
One of the main benefits of testing is ensuring product specification compliance. Checking urea concentration, density, and refractive index helps identify composition deviations before AUS 40 is used. If test results fall outside the specified limits, the product can be evaluated further to minimize the risk of using a non-compliant solution.
Quality Control to Maintain Marine SCR System Performance
Quality control also plays a role in protecting Marine SCR system components. AUS 40 containing excessive contaminants or impurities may increase the risk of deposit formation and interfere with injector and catalyst performance. Over time, these conditions can affect NOx reduction efficiency and increase system maintenance requirements. Therefore, solution purity is an essential aspect that should not be overlooked.
In addition, quality inspections help maintain consistency in the injection process and catalytic reactions. SCR systems require solutions with appropriate characteristics so that AUS 40 dosing can be adjusted according to engine operating conditions. If the solution composition changes, dosing settings and NOx reduction efficiency may also be affected. Maintaining consistent quality helps the system operate more reliably in meeting emission control targets.
Testing should also be conducted regularly, from product acceptance to monitoring during storage and distribution. Samples must be collected using proper procedures to ensure that the test results accurately represent the actual product condition. Testing equipment, such as analytical balances, densitometers, and refractometers, must also be calibrated and operated according to the specified methods.
Storage and Handling to Maintain AUS 40 Quality
Besides laboratory testing, AUS 40 storage and handling also influence product quality. Storage tanks and transfer equipment must be clean and free from potential sources of contamination. Using suitable containers, protecting the solution from extreme temperatures, and following proper handling procedures can help maintain its characteristics until it is used.
Ultimately, AUS 40 quality control is directly connected to efforts to reduce emissions in the maritime sector. An SCR system supported by a solution that meets the required specifications can help reduce NOx emissions from marine engines. This is part of broader efforts to manage the environmental impact of the shipping industry, alongside energy efficiency, engine maintenance, and the implementation of other emission control technologies.
Conclusion
AUS 40 quality parameters under ISO 18611 serve as an important reference for ensuring that the urea solution used in Marine SCR systems meets the required technical specifications. The three main parameters include a urea concentration of 39–41%, a density at 20°C of 1.105–1.177 kg/L, and a refractive index at the same temperature of 1.3947–1.3982.
In addition to these parameters, impurity limits must also be considered to maintain solution purity and reliability. Therefore, regular testing and quality control throughout storage and distribution are essential to ensuring AUS 40 compliance.
By using AUS 40 that meets ISO 18611 specifications, ship operators can support SCR system performance in reducing NOx emissions while maintaining the reliability of exhaust gas treatment components. Consistent quality control is an important step toward more efficient and environmentally responsible ship operations.